Fire Resistant Control Cable (2-4cores) 300-500V

Fire Resistant Control Cable (2-4cores) 300-500V

Model No.︰-

Brand Name︰-

Country of Origin︰China

Unit Price︰CNY ¥ 100 / USD

Minimum Order︰1000 USD

Inquire Now

Product Description

JENUINcable is a Chinese wire and cable manufacturers with more than 20 years of experience in designing, manufacturing, and selling green environmentalprotective wires and cables.we provide xlpe cable,pvc insulated cable,pvc sheathed cable,lszh cable and so on.

 

Fire resistant control cable , the cable refers as multiple cores Cu. The function of mica is to prevent burning when cables catching fire. The cable can maintain the integrity of the electric circuit and continue to work for a period of time when exposed to fire. The sheath is compound material LSFH low smoking free holagen which has little smoking and no toxic gas emission which reduces the damage to the people and equipment. These fire rated control cables we supplied are twisted two layers of mica tape with 80% overlap rate which achieves a good performance of fire resistance.

 

Fire Resistant Control Cable (2-4cores) 300-500V Parameter

 

Conductor

rated voltage 300/500v

 

Without Earth Conductor

With Earth Conductor

No. of Core X Cross Section

No./Nominal Diameter of Strands

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx. Weight

Nominal Overall Diameter

Approx. Weight

No*mm²

No./mm

mm

mm

mm

kg/km

mm

kg/km

2 Cores

2x1.5

7/0.53

0.5

0.5

7.7

70

8.2

80

2x2.5

7/0.67

0.5

0.5

8.8

100

9.6

120

2x4

7/0.85

0.5

0.5

9.8

140

10.5

170

3 Cores

3x1.5

7/0.53

0.5

0.5

8.7

90

10.5

100

3x2.5

7/0.67

0.5

0.5

9.5

125

10.7

150

3x4

7/0.85

0.5

0.5

11.5

180

12.5

220

4 Cores

4x1.5

7/0.53

0.5

0.5

10.3

105

12.2

120

4x2.5

7/0.67

0.5

0.5

11

155

13

190

4x4

7/0.85

0.5

0.5

12.5

255

13.5

270

 

Description of Fire Resistant Control Cable (2-4cores) 300-500V

 

Rated voltage: 300/500V

 

Basic standard: BS 7211

 

Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228  class 2

 

Fire lyer: Mica glass tape

 

Insulation: PVC (XLPE)

 

Sheath: LSZH compound to BS 7655-6.1  

 

Operating temperature range (fixed state): -30°C +90°C

 

Operating temperature range (mobile state): -20°C +50°C

 

Min bending radius: 6 times of Overall Diameter

 

Insulation resistance:  20 MΩ x km (at 20°C)

 

Short circuit temperature:  250°C

 

Circuit Integrity

IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);

 

CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3);

 

NF C32-070-2.3(CR1)

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;

 

VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);

 

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation (Vertically-mounted bundled wires

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-

 

004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;

 

CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;

 

CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;

 

CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

 

Application Of Fire Resistant Control Cable (2-4cores) 300-500V

 

The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.

 

The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.